DVI to fiber extender using 4 core optical fiber transmission RGB data and Clock Clock signals, the resolution up to 1920 x 1200 @ 60 hz, the signal transmission can be single mode or multimode fiber 20 km, 550 meters. Connect the transmitter before use on the monitors will be used, click on the transmitter key, to read and write EDID will be read and stored in the display inside the transmitter, the EDID programming itself so that it is able to adapt to the characteristics of different resolution of display system, make its use more concise, convenient and reliable.
The DVI over fiber convertor support various high definition resolution ratio transmission, the highest can be reach UXGA 1600*1200 or WUXGA 1920*1200@60Hz or HDTV 1080P 1920*1080@60Hz, max bandwidth 4.95Gbps.
SPECIFICATION
Opitcal:
Wavelength |
1310nm&850nm |
Output Power |
-8~-3dBm |
Optic fiber |
50/125u multimode,62.5/125u multimode,9/125u single mode |
Rx sensitivity |
-22dBm |
Optical connector |
4 x LC |
Distance |
0~550M (MM) / 0~20KM (SM) |
Video:
DVI Input/Output | |
Output video |
DVI 1.0 |
Input video signal |
0.5~1.0V P-P |
Input signal DDC |
5V P-P (TTL) |
Connector |
18+1 DVI Male |
General: | |
Input Power |
5 V DC |
Power consumption (maximum) |
2W(max) |
Operating temperature |
-20°C to 70°C |
Storage temperature |
-40°C to 85°C |
Operating humidity |
0 ~ 95% (non-condensing) |
Net Weight |
220g per pair |
Case material |
Aluminum |
Product size |
64mm×52mm×22.5mm( L/W/H) |
Equipment installation and operation
Step 1:Turn on the PC and the monitor power.
Step 2: read the EDID monitor, read methods please follow the steps below:
(1) first connect the 5 v power adapter to the transmitter, ensure the power light red LED lights up.
(2) open the monitor power supply, then connect the transmitter DVI interface launch to the DVI interface display device.
(3) press the transmitter EDID read/write button, the EDID R/W light lights up, says it is to read the EDID information display device. Indicator light goes out after 10 seconds said read EDID information is completed, switch off the power of the transmitter.
Note: if a change in another display device, please do the second step again.
Step 3: first connect the 5 v power adapter to the transmitter, ensure the power light red LED lights up, connect the transmitter DVI interface to the PC of the DVI interface.
Step 4: connect the 5 v power adapter to the receiver, to ensure that the power light red LED lights up. Connect the DVI port of the receiver and display.
Step 5: according to the chart will be LC fiber optic connections, When the 4 core fiber one one corresponding connected, Receiver green lights 1~4 lights up.
For example, large screen splicing applications:
The transmitter can be installed in 19 inch 2U rack-mount chassis, connected multi image processor, after fiber transmission, independent receiver connected with the splicing screen.